TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO.,LTD ESTEL(GUANGDONG) TECHNOLOGY CO., LTD We are the professoinal supplier of outdoor telecom cabinet, air conditioner, heat exchanger, and telecom

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Environmental Monitoring Unit /

DC35V 16mA Smoke Detector For Ourdoor Telecom Cabinet

Contact Now
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MsFiona Liang
Contact Now

DC35V 16mA Smoke Detector For Ourdoor Telecom Cabinet

Ask Latest Price
Video Channel
Brand Name :ESTEL
Model Number :EA4016001
Certification :ISO
Place of Origin :China
MOQ :1PC
Price :Depending on order quantity
Payment Terms :L/C, T/T, Paypal
Supply Ability :20000PCS per month
Delivery Time :15 days
Packaging Details :Carton
Working voltage :DC9V~35V
Standby current :16mA (Relay normally closed) 3mA(Relay normally open)
Alarm current :8mA(Relay normally closed) 19mA(Relay normally open)
Alarm indication :Red LED always on
Sensor :Infrared photoelectric sensor
Working temperature :-10°C ~ +50°C
Anti RF interference :10MHz—1GHz 20V/m
Alarm output :Normally open/normally closed optional, contact capacity DC28V 100mA
more
Contact Now

Add to Cart

Find Similar Videos
Dustproof Rainproof Outdoor 32u Rack Cabinet One Front Door Anti Theft 00:49
Dustproof Rainproof Outdoor 32u Rack Cabinet One Front Door Anti Theft
20U 220VAC Outdoor Telecom Enclosure 19 Inch Rack Cabinet Windproof 00:24
20U 220VAC Outdoor Telecom Enclosure 19 Inch Rack Cabinet Windproof
Single Layer Outdoor Telecom Enclosure DC48V 500W Air Conditioner 00:30
Single Layer Outdoor Telecom Enclosure DC48V 500W Air Conditioner
IP55 Waterproof Outdoor Telecom Cabinet 32U 19 Inch Two Doors 1500W Air Conditioner 150W/K Heat Exchanger 01:43
IP55 Waterproof Outdoor Telecom Cabinet 32U 19 Inch Two Doors 1500W Air Conditioner 150W/K Heat Exchanger
19 Inch IP55 Outdoor Equipment Cabinet Three Point Locking 450mm×460mm×750mm 00:38
19 Inch IP55 Outdoor Equipment Cabinet Three Point Locking 450mm×460mm×750mm
16U Outdoor Telecom Enclosure Weatherproof Electrical Support For Floor Mounted 00:32
16U Outdoor Telecom Enclosure Weatherproof Electrical Support For Floor Mounted
View Product Description

DC9V~35V Smoke Detector For Detecting Smoke And Fire Inside Outdoor Telecom Cabinet

Model: EA4016001

1. Application

The smoke detector can provide protection for communication and electric BTs, and exactly detect smoke. When the concentration of smoke exceeds the preset threshold, the detector alarms and send alarm signal to the control panel. With high volume buzzer, the detector gives high volume sound. The alarm signal doesn’t lock-up, when the density of smog is below the preset threshold, the detector resumes monitoring state. With perfect thunder-proof circuit, the detector can operate normally at bad environment.

2. Product Picture

DC35V 16mA Smoke Detector For Ourdoor Telecom Cabinet

1.LED Indicator light;

2.Dust cover;

3.Maze;

4.Mounting base

3. Product Features

The product is a non coding smoke detector, with a pair of switch output contacts, which can choose the normally open and normally closed output according to the actual needs. In normal operation, the indicator light flashes every 8 seconds; in alarm, the indicator light is always on, and the alarm output contact acts at the same time.

  • Power off reset / automatic reset optional.
  • Alarm output NC / NO optional.
  • 9~35V wide voltage input without polarity (AC, DC).
  • Network output / LED indicator light alarm / buzzer sound alarm standby.
  • SMT manufacturing process, strong stability.
  • Low static current, power saving.
  • Dust proof, insect proof and white light interference resistant design.
  • Metal shielding, anti RF interference (20V/m-1GHz).

4. Technical Parameters

Working voltage DC9V~35V
Standby current 16mA (Relay normally closed) 3mA(Relay normally open)
Alarm current 8mA(Relay normally closed) 19mA(Relay normally open)
Alarm indication Red LED always on
Sensor Infrared photoelectric sensor
Working temperature -10°C ~ +50°C
Environment temperature Max.95%RH (no condensation)
Anti RF interference 10MHz—1GHz 20V/m
Alarm output

Normally open/normally closed optional, contact

capacity DC28V 100mA

Reset mode Automatic reset / power off reset optional
Coverage area When the space height is 6m-12m, the protection area of a detector is 80 square meter for general protection site; when the space height is below 6m, the protection area is 60 square meter. The specific parameters shall be subject to the code for design of automatic fire alarm system GB50116-98.
Executive standard GB4716—2005,EN54—7
Sensitivity 0.5db/m (±0.1db/m)
External dimension 104mm(Diameter)﹡51mm(Height)

5. Product installation

5.1 Select the appropriate installation location, generally installed on the ceiling in the center of the detector coverage area.

5.2 Connect the power line and signal line to the mounting base (mounting base “1” and “2” are no polarity input for power supply; “3” and “4” are alarm output contact).

5.3 Description of blue two digit dial switch

"2" corresponds to KT control switch

"1" corresponds to RST control switch

5.3.1 KT alarm output setting

When the KT switch "2" is pulled to the letter "on", the relay is normally closed.

When the KT switch "2" is pulled to the letter "off", the relay is normally open.

5.3.2 RST alarm mode

When RST switch "1" is pulled to the letter "on", it is automatic reset.

When RST switch "1" is pulled to the letter "off", it is power off reset.

5.4 Screw the mounting base to the ceiling.

5.5 Align the locating convex point at the base end of the detector with the locating groove of the mounting base, and rotate clockwise to install the detector.

6. Notes

6.1 Pay attention to dust prevention. The dust cover can only be removed after the project is officially put into use.

6.2 There shall be no barrier within 0.5m around the detector.

6.3 The horizontal distance between the detector and the air supply hole of the air conditioner shall not be less than 1.5m.

6.4 The horizontal distance between detector and wall, beam edge shall not be less than 0.5m.

6.5 The detector shall be installed in the middle of the inner walkway ceiling with a width of less than 3m. The installation spacing of the detector shall not exceed 15m, and the distance between the detector and the end wall shall not be greater than half of the installation spacing of the control detector.

6.6 The detector should be installed horizontally. In case of inclined installation, the inclination angle should not be greater than 45 degree.

6.7 The detector base shall be installed firmly and its wire connection must be reliable.

6.8 It is recommended to conduct a simulated fire test once half a year to test whether the detector works normally.

7. Installation Inside Outdoor Telecom Cabinet

DC35V 16mA Smoke Detector For Ourdoor Telecom Cabinet

Inquiry Cart 0
You May Like
4G/ WIFI Remote Environmental Monitoring Unit Security Monitoring System Support RS485
4G/ WIFI Remote Environmental Monitoring Unit Security Monitoring System Support RS485
Linux OS EMU Intelligent Monitoring Unit with MODBUS RTU/TCP Support
Linux OS EMU Intelligent Monitoring Unit with MODBUS RTU/TCP Support
19inch 12VDC Environmental Monitoring Unit For Telecom Cabinet
19inch 12VDC Environmental Monitoring Unit For Telecom Cabinet
Easy Operation SNMP 220VAC Environmental Monitoring Unit
Easy Operation SNMP 220VAC Environmental Monitoring Unit
ESTEL RS485 Environmental Monitoring Unit With Web Page
ESTEL RS485 Environmental Monitoring Unit With Web Page
28VDC 10W Door Sensor On Outdoor Telecom Cabinet
28VDC 10W Door Sensor On Outdoor Telecom Cabinet
0.5W 12VDC Water Sensor Preventing Water Leakage
0.5W 12VDC Water Sensor Preventing Water Leakage
DC35V 16mA Smoke Detector For Ourdoor Telecom Cabinet
DC35V 16mA Smoke Detector For Ourdoor Telecom Cabinet
Temperature RS485 MODBUS RTU Environmental Monitoring Unit
Temperature RS485 MODBUS RTU Environmental Monitoring Unit
DC12V 100mA Environmental Monitoring Unit With Alarm
DC12V 100mA Environmental Monitoring Unit With Alarm
AC220V Environmental Rack Monitoring Unit
AC220V Environmental Rack Monitoring Unit
SNMP Environmental Monitoring Unit
SNMP Environmental Monitoring Unit
19inch 12VDC Environmental Monitoring Unit For Telecom Cabinet
19inch 12VDC Environmental Monitoring Unit For Telecom Cabinet
Easy Operation SNMP 220VAC Environmental Monitoring Unit
Easy Operation SNMP 220VAC Environmental Monitoring Unit
ESTEL RS485 Environmental Monitoring Unit With Web Page
ESTEL RS485 Environmental Monitoring Unit With Web Page
Send your message to this supplier
*From:
*To:

TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD

*Subject:
*Message:
Characters Remaining : (0/3000)
Contact Now